AST RESEARCH, INC. TECHNICAL BULLETIN #0768 07-23-92
=============================================================================
AST PREMIUM II 386/33 AND TORUS ETHERNET ADAPTER
PROBLEM: When using the AST Premium II 386/33 with the Torus Ethernet
Adapter in a Microsoft LAN Manager 2.X environment, the system
will fail to map drives or access files on the file server and
will display the error message "DOS Error 5."
CAUSE: The Torus Ethernet is a bus-mastering card that is not
compatible with the Premium II, Premium CLEM, and Bravo 486
series of computers.
AFFECTED
SYSTEMS: AST Premium II systems.
AST Premium CLEM systems.
AST Bravo 486 systems.
SOLUTION: AST Sustaining Engineering has determined that this problem
will not be fixed. AST suggests using an alternate network
interface card.