AST RESEARCH TECHNICAL BULLETIN TB-0180 5-12-86
|
|
|
|
|
|
AST-5251/MODEL 12 VERSION 3.3 WITH IBM SYSTEM/34
|
|
|
|
|
|
The information contained in this Technical Bulletin pertains to
|
|
the AST-5251/Model 12, installed in an IBM Personal Computer,
|
|
that has established connection with an IBM System/34 via
|
|
synchronous modems through a dial-up line.
|
|
|
|
Under the following conditions, a situation can arise whereby the
|
|
PC could exhibit these symptoms:
|
|
|
|
Symptoms:
|
|
|
|
1. The display screen will go blank.
|
|
|
|
2. The "System Available" indicator will stay highlighted.
|
|
|
|
3. Any input from the keyboard will generate an error code
|
|
#0099 and the "Input Inhibit" indicator will be turned
|
|
on. Hitting the error reset key will clear the error
|
|
message. However, any input from the keyboard will still
|
|
generate the error code.
|
|
|
|
Conditions:
|
|
|
|
1. The PC is in emulation mode when a termination
|
|
request is executed.
|
|
|
|
2. There are print jobs still outstanding in the
|
|
System/34's spoolfile when the termination request
|
|
was executed.
|
|
|
|
These symptoms occur due to the fact that the System/34 is
|
|
expecting the spoolfile to be cleared or reset before it
|
|
terminates the connection. In order to bring the PC out of this
|
|
"loop", a shift-shift-ESC key sequence is needed. This will
|
|
bring the PC back to DOS. At this point in time, all previously
|
|
established connections with the System/34 will be lost, and
|
|
normal dial-up procedures are required to bring the PC back on-
|
|
line. It is also important to note that an IBM-5251/Model 12
|
|
will respond in a similar manner given the identical scenario.
|
|
|
|
The suggested solutions to this particular problem are as
|
|
follows:
|
|
|
|
1. Before attempting to execute a termination request,
|
|
check the System/34's spoolfile for any outstanding
|
|
print jobs. If there are print jobs in the spoolfile
|
|
be sure to clear it, and then execute the termination
|
|
request.
|
|
|
|
2. If step #1 is not convenient, then the shift-shift-
|
|
ESC key sequence previously mentioned is required.
|
|
This will bring the PC back to DOS. When this
|
|
procedure is taken, the System/34 will generate an
|
|
SDLC error indicating that it has lost communication
|
|
with the terminal. This System/34 error has to be
|
|
answered before proceeding any further. Now with the
|
|
previous connection terminated, normal dial-up
|
|
procedures are required to bring the PC back on-line.
|
|
|