AST RESEARCH TECHNICAL BULLETIN TB-0285 06/19/87
|
|
|
|
|
|
EEMS/CONCURRENT DOS
|
|
|
|
|
|
|
|
SYMPTOM
|
|
|
|
Parity errors occur in all banks using Concurrent DOS
|
|
Version 5.0 and any AST EEMS board.
|
|
|
|
SOLUTION
|
|
|
|
Perform the following:
|
|
|
|
1. Motherboard memory should be reduced to 256kb. Use
|
|
the AST EEMS board to backfill 384kb for a total of
|
|
640kb conventional memory.
|
|
|
|
2. Copy REMM.SYS from Superpak to Concurrent DOS boot
|
|
disk.
|
|
|
|
3. Rename CCONFIG.EEM to CCONFIG.SYS.
|
|
|
|
4. In CCONFIG.SYS, change the statement EEM=EMM.SYS to
|
|
read EEM=REMM.SYS.
|
|
|
|
NOTES
|
|
|
|
The following equipment and software were used:
|
|
|
|
1. IBM AT
|
|
2. Advantage Premium
|
|
3. Rampage AT
|
|
4. Rampage 286
|
|
5. Superpak version 6.1, version 6.2
|
|
6. Concurrent DOS Version 5.0 Digital Research
|
|
|