AST RESEARCH, INC. TECHNICAL BULLETIN #TB-0359 1-6-88
|
|
|
|
|
|
AST ETHERNET/ERROR "08"
|
|
|
|
|
|
The IC at location U8 on the AST-Ethernet board has been
|
|
discovered to be faulty. The problem if it occurs, most
|
|
commonly manifest itself as an error "08" during AST-Ethernet
|
|
power on self test. If the board is properly configured and
|
|
terminated but still exhibits this failure, examine the IC at
|
|
location U8. If it is an 82C501, the problem is probably due
|
|
to a faulty IC. If the part at this location is a 8023A,
|
|
however, then the problem most likely lies elsewhere.
|
|
|
|
|
|
|
|
|