Files
2021-04-15 13:31:59 -05:00

28 lines
1.2 KiB
Plaintext

=============================================================================
AST RESEARCH, INC. TECHNICAL BULLETIN #0552A 05/16/90
=============================================================================
AST-3270 COAXII-CUT FTS-II FUNCTIONAL ISSUES
AST Data Comm Product Marketing has reviewed all aspects of the following
functional issues relating to the COAXII FTS-II product. They have made the
determination that these issues will not be resolved for this product.
These issues are as follows:
- User has DOS/VSE/CICS installed on host and is running "VSE/SP
Intelligent Workstation Support" facility. When attempting a file
transfer, the error message "INW0007I ERROR IN HOST TRANSFER FILE -
TRANSFER TERMINATED" is generated. The "Intelligent Workstation
Support" facility is not supported with COAXII-CUT software or FTS-II.
(PR#B41002)
- When downloading files which have record lengths of 80 characters, the
FTS-II software will either duplicate or omit some of the records at
random places in the file. The host system where this occurs is running
under VM/CMS Release 4. (PR#B41010)