Telenet ITI Parameters
|
|
----------------------
|
|
|
|
|
|
Summary of Telenet ITI Parameters
|
|
---------------------------------
|
|
|
|
Para- Para-
|
|
meter Description (Default Value) meter Description (Default Value)
|
|
----- --------------------------- ----- ---------------------------
|
|
1 Line feed Insertion (0) 31+ Interrupt Character (0)
|
|
2 Network Message Display (0) 32 Automatic Hang-up (0)
|
|
3 Echo (1) 33+ Flush Output (0)
|
|
4 Echo Mask (163) 34 Transmit on Timers (1)
|
|
5 Transmit Mask (2) 35 Idle Timer (80)
|
|
6* Buffer Size (0) 36 Interval Timer (0)
|
|
7* Command Mask (127) 37 Network Usage Display (0)
|
|
8* Command Mask (3) 38 Carriage Return PAD (Variable)
|
|
9 Carriage Return PAD (Fixed) 39 Padding Options (1)
|
|
10 Linefeed Padding 40 Insert on Break (0)
|
|
|
|
11 Tab Padding 41 PAD-Terminal Flow Control (0)
|
|
12 Line Width 42 PAD-Terminal XON Character (17)
|
|
13 Page Length (0) 43 PAD-Terminal XOFF Character (19)
|
|
14 Line Folding (1) 44* Generate Break (INV)
|
|
15 Page Wait (0) 45* APP on Break (0)
|
|
16 Interrupt on Break (0) 46 Input Unlock Option (0)
|
|
17 Break Code (0) 47 Input Unlock Timer (0)
|
|
18 NVT Options (0) 48 Input Unlock Character (0)
|
|
19 Initial Keyboard State (0) 49 Output Lock Option (2)
|
|
20 Half/Full Duplex 50 Output Lock Timer (10)
|
|
|
|
21 Real Character Code 51 Output Lock Option (0)
|
|
22 Printer Style 53* Break Options (0)
|
|
23 Terminal Type 54 Terminal-PAD Flow Control (0)
|
|
24 Permanent Terminal (0) 55 Terminal-PAD XON Character (17)
|
|
25 Manual or Auto Connect (0) 56 Terminal-PAD XOFF Character (19)
|
|
26 Rate 57 Connection Mode (2)
|
|
27 Delete Character (127) 58 Escape to Command Mode (1)
|
|
28 Cancel Character (24) 59* Flush Output on Break (0)
|
|
29 Display Character (18) 60 Delayed Echo
|
|
30+ Abort Output Character (0) 63 Eight-bit Transparency (1)
|
|
64+ Early ACK (0)
|
|
65 More-Data Bit Generation (3)
|
|
66 Defer Processing of User (0)
|
|
67 ESP Packetizing Option (0)
|
|
68 Escape Sequence Timer (0)
|
|
69 Escape Sequence Maximum Length (0)
|
|
70 Escape Sequence Initiator (0)
|
|
71 Parameter Reset on Disconnect (0)
|
|
|
|
Note: All Telenet Parameters must follow the National Option Marker
|
|
(Parameter 0, value '21' Hex) in PAD Messages.
|
|
|
|
Parameters marked with "*" should not be used.
|
|
|
|
Parameters marked with "+" should be used with caution.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Telenet ITI Parameters Arranged by Functional Category
|
|
------------------------------------------------------
|
|
|
|
Para- Para-
|
|
meter Description (Default Value) meter Description (Default Value)
|
|
----- --------------------------- ----- ---------------------------
|
|
|
|
(CONNECTION MODE) (BREAK HANDLING)
|
|
57 Connection Mode (2) 16 Interrupt on Break (0)
|
|
58 Escape to Command Mode (1) 40 Insert on Break (0)
|
|
17 Break Code (0)
|
|
(CALL ESTABLISHMENT & CLEARING) 44* Generate Break (INV)
|
|
25 Manual or Auto Connect (0) 45* APP on Break (0)
|
|
32 Automatic Hang-up (0) 59* Flush Output on Break (0)
|
|
53* Break Options (0)
|
|
(COMMAND PROTECTION)
|
|
7* Command Mask (127) (VIRTUAL TERMINAL DEVICE)
|
|
8* Command Mask (3) 39 Padding Options (1)
|
|
9 Carriage Return PAD (Fixed)
|
|
(DEVICE DEPENDENT) 38 Carriage Return PAD (Variable)
|
|
24 Permanent Terminal (0) 10 Linefeed Padding
|
|
23 Terminal Type 11 Tab Padding
|
|
20 Half/Full Duplex 12 Line Width
|
|
21 Real Character Code 13 Page Length (0)
|
|
22 Printer Style 14 Line Folding (1)
|
|
26 Rate 15 Page Wait (9)
|
|
63 Eight-bit Transparency (1) 1 Linefeed Insertions (0)
|
|
|
|
(TERMINAL DISPLAY) (VIRTUAL TERMINAL PROCESS)
|
|
3 Echo (1) 18 NVT Options (0)
|
|
4 Echo Mask (163) 27 Delete Character (127)
|
|
2 Network Message Display (0) 28 Cancel Character (24)
|
|
37 Network Usage Display (0) 29 Display Character (18)
|
|
60 Delayed Echo (0) 31 Interrupt Character (0)
|
|
30 Abort Output Character (0)
|
|
(PACKET ASSEMBLY/DISASSEMBLY) 33 Flush Output (0)
|
|
6* Buffer Size (0)
|
|
5 Transmit Mask (2)
|
|
34 Transmit on Timers (1) (2741 Terminal Support)
|
|
35 Idle Timer (80) 19 Initial Keyboard State (0)
|
|
36 Interval Timer (0) 46 Input Unlock Option (0)
|
|
60 Delayed Echo 47 Input Unlock Timer (0)
|
|
64 Early ACK (0) 48 Input Unlock Character (0)
|
|
65 More-Data Bit Generation (3) 49 Output Lock Option (2)
|
|
50 Output Lock Timer (10)
|
|
(RESELECT HANDLING) 51 Output Lock Option (0)
|
|
66 Defer Processing of Input
|
|
71 Parameter Reset on Disc (0) (ESCAPE SEQUENCE PROCESSING)
|
|
67 ESP Packetizing Option (0)
|
|
(FLOW CONTROL) 68 Escape Sequence Timer (0)
|
|
41 PAD-Terminal Flow Control (0) 69 Escape Sequence Length (0)
|
|
42 PAD-Terminal XON Character (17) 70 Escape Sequence Initiator (0)
|
|
43 PAD-Terminal XOFF Character (19)
|
|
54 Terminal-PAD Flow Control (0)
|
|
55 Terminal-PAD XON Character (17)
|
|
56 Terminal-PAD XOFF Character (19)
|
|
|
|
|
|
Parameters marked with "*" should not be used.
|
|
|
|
|
|
Detail of Telenet ITI Parameters
|
|
|
|
Following is a description of each of the Telenet ITI parameters. Defaults
|
|
for Telenet Public Dial Ports are noted
|
|
|
|
As noted by (+) use the equivalent X.3 parameter wherever possible
|
|
|
|
Parameters marked (*) are archaic and should not be used.
|
|
|
|
|
|
Para-
|
|
meter Description
|
|
----- -----------
|
|
|
|
+1 Linefeed Insertion
|
|
|
|
This parameter instructs the PAD to routinely insert a linefeed
|
|
(LF) character into the data stream following each appearance of a
|
|
carriage return (CR) character. Values may be OR-ed together:
|
|
|
|
0 No LF Insertion (Default)
|
|
1 Insert LF after CR on output to the terminal
|
|
2 Insert LF after CR on input from the terminal
|
|
4 Insert LF after CR on echo to the terminal
|
|
|
|
|
|
+2 Network Message Display
|
|
|
|
This parameter controls the transmission of network-oriented
|
|
messages to the terminal. Values are:
|
|
|
|
0 Transmit network-oriented messages (Default)
|
|
1 Suppress network-oriented messages
|
|
|
|
|
|
+3 Echo
|
|
|
|
This specifies whether or not the network returns images of
|
|
characters entered from the terminal during Data Transfer mode.
|
|
Values are:
|
|
|
|
0 Network does not echo
|
|
1 Network echoes according to the Echo Mask (Default)
|
|
|
|
|
|
4 Echo Mask
|
|
|
|
The Echo Mask specifies which characters are to be echoed during
|
|
Data Transfer mode. Values may be OR-ed together:
|
|
|
|
1 Alphanumerics
|
|
2 Carriage Return
|
|
4 Escape
|
|
8 Editing Characters
|
|
16 Terminators
|
|
32 Form Effectors
|
|
64 Control Characters
|
|
128 Other Characters
|
|
|
|
Default is 163 = 1+2+32+128 (Alphanumerics, Carriage Return, Form
|
|
Effectors, and Other Characters).
|
|
|
|
|
|
+5 Transmit Mask
|
|
|
|
The Transmit Mask specifies those characters which indicate a
|
|
logical break in the data being entered from a terminal and which
|
|
force transmission of that data to its destination. Values may be
|
|
OR-ed together:
|
|
|
|
0 Transmission on Transmit Mask disabled
|
|
1 Alphanumerics
|
|
2 Carriage Return (Default)
|
|
4 Escape
|
|
8 Editing Characters
|
|
16 Terminators
|
|
32 Form Effectors
|
|
64 Control Characters
|
|
128 Other Characters
|
|
|
|
Note: see Character Codes and Masking Categories below
|
|
|
|
|
|
*6 Buffer Size
|
|
|
|
This parameter is archaic and should no longer have any affect on a
|
|
TP. It is used to specify the maximum number of characters that
|
|
will be accumulated by the network before they are forwarded to the
|
|
Host.
|
|
|
|
0 Buffer 256 characters (Default)
|
|
1-255 Buffer 1-255 characters
|
|
|
|
|
|
*7 Command Mask
|
|
|
|
This is an archaic parameter. Its use has been phased out, but the
|
|
parameter number has not be redefined for another function.
|
|
|
|
|
|
*8 Command Mask
|
|
|
|
This is an archaic parameter which has not been redefined to
|
|
support another function.
|
|
|
|
|
|
+9 Carriage Return Padding
|
|
|
|
The Carriage Return Padding parameters specify the number of PAD
|
|
character times to be inserted after each carriage return
|
|
character sent to the terminal. Parameter 9 specifies the Fixed
|
|
Component. Values may run from 0 through 31 character-times of
|
|
padding provided.
|
|
|
|
|
|
+10 Linefeed Padding
|
|
|
|
This specifies the number of pad character delays inserted after
|
|
each linefeed (LF) character sent to the terminal. Values may
|
|
range from 0 through 15 character-times of padding provided.
|
|
|
|
|
|
11 Tab Padding
|
|
|
|
This specifies the number of pad character delays inserted after
|
|
each horizontal tabulation (HT) character sent to the terminal.
|
|
Values may range from 0 through 15 character-times of padding
|
|
provided.
|
|
|
|
|
|
12 Line Width
|
|
|
|
This identifies the number of character positions per terminal
|
|
print line. Values range from 1 through 255 characters per line;
|
|
or 0, which specifies 256 characters per line.
|
|
|
|
|
|
13 Page Length
|
|
|
|
This parameter identifies the number of lines per terminal page or
|
|
display screen. Values range from 1 through 255 lines per page; or
|
|
0, which specifies an infinite page length.
|
|
|
|
|
|
14 Line Folding
|
|
|
|
This parameter specifies whether or not the PAD begins a new line
|
|
when the number of characters in a print line exceeds the line
|
|
width:
|
|
|
|
0 Disable line folding
|
|
1 Enable line folding (Default)
|
|
|
|
|
|
15 Page Wait
|
|
|
|
This parameter specifies whether or not the PAD automatically
|
|
enters a flow controlled state (X-OFFed) at the end of each page.
|
|
Page length is defined by Telenet parameter 13, above.
|
|
|
|
0 Page Wait disabled (Default)
|
|
1 Page Wait enabled
|
|
|
|
|
|
+16 Interrupt on Break
|
|
|
|
This parameter specifies whether or not the PAD will transmit an
|
|
INTERRUPT packet to the Host when a break signal is received from
|
|
the terminal. Values are:
|
|
|
|
0 No INTERRUPT packet sent on break (Default)
|
|
1 Send INTERRUPT packet on break
|
|
|
|
|
|
17 Break Code
|
|
|
|
The Break Code specifies an eight-bit representation for the break
|
|
signal condition. Codes may be any number from 1 through 255.
|
|
Default is 0 (No break code).
|
|
|
|
|
|
+18 Network Virtual Terminal (NVT) Option
|
|
|
|
This parameter enables or disables NVT facilities by functional
|
|
group (The Process Control function should no longer be used):
|
|
|
|
0 NVT disabled (Default)
|
|
2 Enables Process Control function *
|
|
4 Enables Editing Function
|
|
|
|
* use with caution
|
|
|
|
|
|
*19 Initial Keyboard State
|
|
|
|
This archaic parameter defined the initial state of the terminal
|
|
keyboard at the beginning of a virtual call.
|
|
|
|
0 Keyboard initially locked (Default)
|
|
1 Keyboard initially unlocked
|
|
|
|
|
|
20 Half/Full Duplex
|
|
|
|
This parameter specifies the echoing requirement of the terminal.
|
|
Values are:
|
|
|
|
0 Full duplex terminal
|
|
1 Half duplex terminal
|
|
|
|
|
|
*21 Real Character Code
|
|
|
|
This parameter specified the communications code for representing
|
|
data generated or recognized by the terminal. Values are:
|
|
|
|
0 ASCII
|
|
1 Correspondence (standard Selectric)
|
|
2 EBCD
|
|
3 APL ASCII (typewriter-paired)
|
|
4 APL ASCII (bit-paired)
|
|
5 APL Correspondence
|
|
6 APL EBCD
|
|
|
|
|
|
22 Printer Style
|
|
|
|
This identifies the class of printing mechanism used by the
|
|
terminal:
|
|
|
|
0 Typewriter style terminal
|
|
1 Line printer style terminal
|
|
|
|
|
|
23 Terminal Type
|
|
|
|
This identifies the specific make and model of the terminal.
|
|
Values are:
|
|
|
|
0 Unknown or Synchronous Host
|
|
1-126 Terminal codes
|
|
127 Asynchronous Hosts
|
|
|
|
|
|
24 Permanent Terminal
|
|
|
|
This determines whether the network queries for a terminal
|
|
identifier or employs a pre-set identifier. Values are:
|
|
|
|
0 Request identifier (Default)
|
|
1 Use pre-set identifier
|
|
|
|
|
|
25 Manual/Automatic Connection
|
|
|
|
This parameter specifies whether a pre-defined virtual circuit is
|
|
to be established automatically for the terminal, or it the call
|
|
must be initiated by a C(onnect) or ID command entered from the
|
|
terminal. Values are:
|
|
|
|
0 Manual (Connect or ID required) (Default)
|
|
1 Automatic (Address pre-defined)
|
|
|
|
|
|
+26 Rate
|
|
|
|
This parameter specifies the transmission speed of the terminal,
|
|
as determined by the network:
|
|
|
|
0 110 bps
|
|
1 134.5
|
|
2 300
|
|
3 1200
|
|
4 600
|
|
5 75
|
|
6 150
|
|
7 1800
|
|
8 200
|
|
9 100
|
|
10 50
|
|
11 75/1200
|
|
12 2400
|
|
13 4800
|
|
14 9600
|
|
15 19,200
|
|
16 48,000
|
|
17 56,000
|
|
18 64,000
|
|
|
|
|
|
+27 Delete Character
|
|
|
|
This specifies the character to be used for single-character
|
|
editing.
|
|
|
|
0 Function disabled
|
|
1-127 Identifies the character to be used
|
|
|
|
Default is decimal 127.
|
|
|
|
|
|
+28 Cancel Character
|
|
|
|
Specifies the character to be used to delete input data buffered
|
|
for the terminal at the PAD.
|
|
|
|
0 Function disabled
|
|
1-127 Identifies the character to be used
|
|
|
|
Default is decimal 24.
|
|
|
|
|
|
+29 Display Character
|
|
|
|
Specifies the character to be used for displaying data which has
|
|
been accumulated by the PAD.
|
|
|
|
0 Function disabled
|
|
1-127 Identifies the character to be used
|
|
|
|
Default is decimal 18.
|
|
|
|
|
|
*30 Abort Character
|
|
|
|
This is an NVT Process Control parameter and should no longer be
|
|
used. If NVT Process Control was enabled (Telenet 18:2), then
|
|
this parameter specified the character which, when received from
|
|
the terminal, caused the PAD to Flush Output (Telenet 33:1) and
|
|
generate an X.25 INTERRUPT containing F5 hex in the optional data
|
|
byte. Note, data remained flushed until X.3 parm 8 or Telenet
|
|
parm 33 was reset to zero.
|
|
|
|
0 Function disabled (Default)
|
|
1-127 Identifies the character to be used
|
|
|
|
|
|
*31 Interrupt Character
|
|
|
|
This is an NVT Process Control parameter and should no longer be
|
|
used. If NVT Process Control was enabled (Telenet 18:2), then
|
|
this parameter specified the character which, when received from
|
|
the terminal, caused the PAD to generate an X.25 INTERRUPT
|
|
containing F4 hex in the optional data byte.
|
|
|
|
0 Function disabled (Default)
|
|
1-127 Identifies the character to be used
|
|
|
|
|
|
32 Automatic Hang Up
|
|
|
|
This specifies whether the terminal is to be physically
|
|
disconnected from the network or left in Command Mode at the end
|
|
of a virtual call. Values are:
|
|
|
|
0 Leave in Command Mode upon disconnect (Default)
|
|
1 Hang up upon disconnect
|
|
|
|
|
|
+33 Flush Output
|
|
|
|
This parameter controls the transmission of all data from the Host
|
|
to the terminal:
|
|
|
|
0 Transmit all information sent from (Default)
|
|
the Host to the terminal
|
|
|
|
1 Discard all information sent from
|
|
the Host to the terminal
|
|
|
|
|
|
34 Transmit on Timers
|
|
|
|
This specifies that characters accumulated by the network are
|
|
forwarded upon expiration of either the Idle or Interval Timer.
|
|
Values are:
|
|
|
|
0 Disable transmission on timers
|
|
1 Enable transmission on timers (Default)
|
|
|
|
|
|
+35 Idle Timer
|
|
|
|
The Idle timer defines the time interval between characters
|
|
arriving from the terminal which, when exceeded, causes the
|
|
network to transmit any accumulated characters to the Host.
|
|
Values are:
|
|
|
|
0 Timer disabled
|
|
2-255 Multiples of 50 ms (.05 seconds)
|
|
|
|
Note: Default is 80 (4 seconds)
|
|
|
|
|
|
36 Interval Timer
|
|
|
|
The Interval Timer specifies the maximum time period during which
|
|
the network PAD will accumulate characters before forwarding them
|
|
to their destination. Values are:
|
|
|
|
0 Timer disabled (Default)
|
|
2-255 multiples of 50 ms (.05 seconds)
|
|
|
|
|
|
37 Network Usage Display
|
|
|
|
This controls the transmission of information on chargeable network
|
|
usage provided at the end of a virtual call. Values are:
|
|
|
|
0 Exclude network-generated usage information
|
|
from the DISCONNECTED message (Default)
|
|
|
|
1 Include network-generated usage information
|
|
from the DISCONNECTED message
|
|
|
|
|
|
38 Carriage Return Padding (Variable)
|
|
|
|
This specifies the amount of time-delay padding to be provided
|
|
after each carriage return sent to the terminal, for every 10
|
|
printable characters on the line (E.g., no padding for nine
|
|
characters; five time the value of parameter 38 for 50 characters.)
|
|
Values may run from 0 through 7.
|
|
|
|
|
|
39 Padding Options
|
|
|
|
This parameter specifies whether or not the network provides time
|
|
delay padding after form effectors sent to the terminal. Values
|
|
are:
|
|
|
|
0 Network provides no time delay padding
|
|
|
|
1 Network provides time delay padding (Default)
|
|
after CR, LF, and HT characters
|
|
|
|
|
|
40 Insert on Break
|
|
|
|
This specifies whether or not the PAD inserts the Break Code in the
|
|
data stream at the point at which the break signal is received from
|
|
the terminal. Values are:
|
|
|
|
0 Do not insert on break (Default)
|
|
1 Insert Break Code on break
|
|
|
|
|
|
+41 PAD-to-Terminal Flow Control
|
|
|
|
This parameter specifies network XON/XOFF control of transmission
|
|
from the terminal. Values are:
|
|
|
|
0 No PAD-to-Terminal Flow Control (Default)
|
|
1 Network provides flow control
|
|
|
|
|
|
42 PAD-to-Terminal XON Character
|
|
|
|
This identifies the character which, when sent from the network to
|
|
the terminal, causes the terminal to resume transmission of
|
|
buffered data. Value may be any character from 1 to 127. Default
|
|
is 17 (19 octal, 11 hex).
|
|
|
|
|
|
43 PAD-to-Terminal XOFF Character
|
|
|
|
This identifies the character which, when sent from the network to
|
|
the terminal, causes the terminal to temporarily suspend
|
|
transmission of buffered data. Value may be any character from 1
|
|
to 127. Default is 19 (21 octal, 13 hex).
|
|
|
|
|
|
*44 Generate Break
|
|
|
|
This parameter used to cause a break signal to be transmitted
|
|
from the PAD to the terminal. It is no longer valid to set this
|
|
parameter.
|
|
|
|
|
|
*45 APP on Break
|
|
|
|
This parameter specified whether or not the PAD transmitted a
|
|
SET & READ PARAMETERS PAD Message to the Host system when a break
|
|
signal was received from the terminal. This parameter should no
|
|
longer be used.
|
|
|
|
0 No SET & READ PARAMETERS PAD Message (Default)
|
|
generated on break
|
|
|
|
1 SET & READ PARAMETERS PAD Message generated
|
|
on break
|
|
|
|
|
|
*46 Input Unlock Option
|
|
|
|
This archaic parameter specifies what action the PAD took after the
|
|
terminal user had entered a line of data, the keyboard had been
|
|
locked, and the PAD had no data to deliver to the terminal. Values
|
|
are:
|
|
|
|
0 Unlock based on timer expiration (Default)
|
|
1 Unlock based on input data content
|
|
|
|
|
|
*47 Input Unlock Timer
|
|
|
|
This archaic parameter specified the time interval that the PAD
|
|
would wait before unlocking the terminal keyboard, if the PAD had
|
|
no data pending delivery to the terminal and parameter 46 was set
|
|
to 0. Values ranged from 0 through 255 multiples of 50 ms (.05
|
|
seconds). Default was 0 seconds.
|
|
|
|
|
|
*48 Input Unlock Character
|
|
|
|
This archaic parameter specified the character which, when appearing
|
|
at the beginning of a data line, caused the PAD to leave the keyboard
|
|
locked at the end of the data line (if there is no data pending
|
|
delivery to the terminal). Value was any character code from 0
|
|
through 127; or 240, which leaves the keyboard locked after all
|
|
characters. Default was 0.
|
|
|
|
|
|
*49 Output Lock Option
|
|
|
|
This archaic parameter specified the action the PAD took when it
|
|
received data for delivery to the terminal, when the keyboard was
|
|
unlocked for input from the terminal. Values are:
|
|
|
|
0 Discard output data
|
|
1 Transmit output after input completion
|
|
2 Transmit output id input idle (Default)
|
|
|
|
|
|
*50 Output Lock Timer
|
|
|
|
This archaic parameter defined the interval between characters
|
|
arriving from the terminal which, when exceeded, caused the PAD
|
|
to lock the keyboard when it had output pending delivery to the
|
|
terminal. Values may range from 0 through 255 multiples of 50 ms
|
|
(.05 seconds). Default was 10 (500ms).
|
|
|
|
|
|
*51 Output Lock Option
|
|
|
|
This archaic parameter specified what action the PAD took after it
|
|
had transmitted all pending data to the terminal. Values are:
|
|
|
|
0 Unlock based on timer (Default)
|
|
1 Unlock based on output completion
|
|
2 Unlock based on output data content
|
|
|
|
|
|
+53 Break Options
|
|
|
|
This allows for a combination of options for handling break signals
|
|
from the terminal. Values may be OR-ed together:
|
|
|
|
0 No options selected (Default)
|
|
1 Interrupt on break
|
|
4 APP on break
|
|
32 Insert on break
|
|
|
|
Note, X.3 parameter 7 should be used instead of this parameter
|
|
|
|
|
|
54 Terminal-to-PAD Flow Control
|
|
|
|
This parameter specifies XON/XOFF control of transmission from the
|
|
network. Values are:
|
|
|
|
0 No Terminal-to-PAD flow control (Default)
|
|
1 Network respects flow control
|
|
|
|
|
|
55 Terminal-to-PAD XON Character
|
|
|
|
This identifies the character which, when sent to the network,
|
|
causes the network to resume the transmission of buffered data.
|
|
Value may be any character code from 1 through 127. Default is 17
|
|
decimal.
|
|
|
|
|
|
56 Terminal-to-PAD XOFF Character
|
|
|
|
This identifies the character which, when sent to the network,
|
|
causes the network to temporarily suspend the transmission of
|
|
buffered data. Value may be any character code from 1 through 127.
|
|
Default is 19.
|
|
|
|
|
|
57 Connection Mode
|
|
|
|
This parameter specifies which level of terminal code conversion
|
|
the PAD is to perform during data transfer mode. Values are:
|
|
|
|
0 Transparent
|
|
1 Real
|
|
2 Virtual (Default)
|
|
|
|
|
|
+58 Connection Escape
|
|
|
|
This parameter specifies whether or not the terminal may escape
|
|
from Data Transfer mode to Network Command mode. Values are:
|
|
|
|
0 Escape not possible
|
|
1 Escape possible (Default)
|
|
|
|
|
|
*59 Flush Output on Break
|
|
|
|
This parameter specified whether or not the PAD transmitted a SET &
|
|
READ PARAMETER PAD Message to the Host and began discarding output
|
|
to the terminal when a break signal was received from the terminal.
|
|
Rather than using this parameter set X.3 parameter 7 to 21
|
|
(decimal).
|
|
|
|
0 No SET & READ PARAMETERS PAD Message (Default)
|
|
sent and no output flushed
|
|
|
|
1 SET & READ PARAMETERS PAD Message sent and output
|
|
to the terminal
|
|
|
|
|
|
60 Delayed Echo
|
|
|
|
This parameter identified whether echo from the PAD to the terminal
|
|
will occur immediately or whether it will be delayed to appear
|
|
between data from incoming packets. If 60:1, then once the PAD has
|
|
begun processing an incoming packet, it will buffer echo characters
|
|
until it completes the packet. At that point, it will transmit all
|
|
buffered echo characters back to the terminal before processing the
|
|
next incoming packet. Values are:
|
|
|
|
0 Echo immediately (Default)
|
|
1 Delay echo to occur between incoming packets
|
|
|
|
|
|
63 Eight-bit Transparency
|
|
|
|
This parameter identifies whether the terminal uses the eighth
|
|
(most significant) bit for data or as a parity bit. Note, if
|
|
Telenet parameter 57:2, this parameter cannot be set to zero.
|
|
Values are:
|
|
|
|
0 No parity, eight-bit transparency
|
|
1 Parity required (Default)
|
|
|
|
|
|
64 Early ACK
|
|
|
|
This parameter specifies whether or not the PAD for terminal
|
|
support should acknowledge data packets received for the terminal
|
|
prior to transmitting the packets (in the form of a character
|
|
stream) to the terminal. Values are:
|
|
|
|
0 Acknowledge data packets after transmission
|
|
to the terminal (Default)
|
|
|
|
1-7 Acknowledge data packets 1-7 packets prior to
|
|
transmission to the terminal
|
|
|
|
Note: *Extreme Caution* should be exercised when modifying this
|
|
parameter. The increased "artificial window" size does not
|
|
guarantee packet delivery to the terminal. Large amounts of
|
|
data could be lost from any form of network disconnect.
|
|
Values of 5 or greater should never be used.
|
|
|
|
|
|
65 M-bit handling
|
|
|
|
This parameter specifies whether the terminal PAD will set the M-bit
|
|
on all full packets, on certain full packets, or on packets. Values
|
|
are:
|
|
|
|
0 M-bit is always zero
|
|
1 M-bit is set to one for certain full packets
|
|
3 M-bit is set to one in all full packets (Default)
|
|
|
|
If parameter 65:1, the PAD will set the M-bit on all full packets
|
|
except where the last user-entered character is a data-forwarding
|
|
character, as defined by X.3 parameter 3 (Transmit Mask). If,
|
|
however, the final character in the packet is a carriage return and
|
|
X.3 parameter 13 causes a line feed insertion following the carriage
|
|
return and X.3 parameter 3 marks carriage return as a data-forwarding
|
|
character, then the M-bit will be set to 1. The PAD will then
|
|
transmit a second packet, with M-bit set to 0, containing only a
|
|
line feed character.
|
|
|
|
If, after sending a packet with M-bit set to one, the PAD must send
|
|
a data-qualified packet (Q-bit=1), this is considered a data-
|
|
forwarding condition. Thus, the PAD will send a data packet with
|
|
M-bit = 0 containing the characters currently in its buffer. If
|
|
the buffer is empty the PAD will send an empty packet with M-bit = 0.
|
|
This prevents a protocol violation.
|
|
|
|
|
|
66 Defer Processing of User Input
|
|
|
|
This parameter instructs the PAD to halt processing of user input
|
|
data and buffer the data (to a maximum of 32-64 characters). Upon
|
|
disconnect, parameter 66 is rest and processing of user data resumes.
|
|
If the disconnect triggers a reselection (e.g., forwarding of the
|
|
call by TAMS), the buffered data is sent to the new called DTE
|
|
Otherwise, or if reselection fails, the data is interpreted by the
|
|
PAD as a command during command mode. Values are
|
|
|
|
0 Process user input normally (Default)
|
|
1 Defer processing of user input data
|
|
|
|
67 ESP Packetizing Option
|
|
|
|
This parameter specifies whether accumulated data is to be packet-
|
|
izied when the Escape Sequence Initiator is received (i.e., before
|
|
the Escape Sequence) and when the Escape Sequence is completed.
|
|
Values are:
|
|
|
|
Packetize Packetize
|
|
Before After
|
|
|
|
0 No No (Default)
|
|
1 No Yes
|
|
2 Yes No
|
|
3 Yes Yes
|
|
|
|
|
|
68 Escape Sequence Timer
|
|
|
|
This parameter specifies the maximum idle time allowed before ESP
|
|
processing expires. Values range from zero through 255 and
|
|
represent 50 ms intervals. Resolution of the timer is zero to
|
|
minus 50 ms (e.g., a value of 2 represents 50ms < timer < 100ms).
|
|
Default is zero.
|
|
|
|
|
|
69 Escape Sequence Maximum Length
|
|
|
|
This parameter specifies the maximum number of characters that may
|
|
be contained in an Escape Sequence, including the Escape Sequence
|
|
Initiator. A value of zero disables parameter 69 and the maximum
|
|
Escape Sequence is 128 characters. Default is zero and values
|
|
greater than 127 are not allowed.
|
|
|
|
|
|
70 Escape Sequence Initiator
|
|
|
|
This parameter specifies the seven-bit representation of the Escape
|
|
Sequence Initiator character (values 1-127). The default value of
|
|
zero disables Escape Sequence Processing altogether.
|
|
|
|
|
|
71 Parameter Reset on Disconnect
|
|
|
|
This parameter specifies the manner in which parameters are to be
|
|
treated upon disconnect. Values are:
|
|
|
|
0 Reset ITIs to their initial values (Default)
|
|
1 Do not reset ITIs, except for reselect-related
|
|
parameters (66 and 71)
|
|
2 Do not reset ITIs, except set 66:0 and 71:1
|
|
3 Do not reset ITIs, except set 66:0
|
|
|
|
Value 1 makes parameter 71 a "one-shot" parameter, this is it
|
|
clears itself after being invoked once. Value 2 is a "two-shot"
|
|
value and value 3 leaves parameter 71 active until explicitly
|
|
reset.
|
|
|