AST RESEARCH TECHNICAL BULLETIN TB-0002 4-16-84
|
|
|
|
POWER-ON SELF TEST ERROR ON XT AND PORTABLE COMPUTERS
|
|
|
|
|
|
When the IBM-XT or portable computer is powered-on, the system
|
|
BIOS initializes a Power-On Self Test (POST). In the upper left-
|
|
hand corner of the screen, the progress of the POST is displayed
|
|
in the format:
|
|
|
|
XXX KB OK
|
|
|
|
The number (XXX) should continue to increase until it equals the
|
|
amount of memory installed in the system. Normally, this test
|
|
takes 23 to 90 seconds to complete, depending on the amount of
|
|
memory installed. Upon completion, the system will attempt to
|
|
boot the diskette in drive A.
|
|
|
|
However, if switch 1 of the switch system board switch block is
|
|
"ON", the POST will re-initialize and start over. This will
|
|
continue in an endless loop.
|
|
|
|
This problem can be resolved by removing power from the system,
|
|
positioning switch 1 in the "OFF" position and then re-applying
|
|
power to the system.
|
|
|
|
The IBM Guide to Operations refers to this switch only as "Normal
|
|
operation; always off".
|
|
|