AST RESEARCH TECHNICAL BULLETIN TB-0012 5-16-84
|
|
|
|
|
|
MEGAPLUS II IRQ SILKSCREEN CONFLICT
|
|
|
|
|
|
In certain revisions of the MegaPlus II, the silkscreen for the
|
|
IRQ block is in error. The correct silkscreen for the IRQ jumper
|
|
block should be:
|
|
|
|
* * * * * * * * *
|
|
< JUMPER BLOCK
|
|
* * * * * * * * *
|
|
CORRECT
|
|
2 2 3 3 4 4 5 5 7
|
|
|
|
S C S C C S C
|
|
|
|
The incorrect silkscreen is as follows:
|
|
|
|
* * * * * * * * *
|
|
< JUMPER BLOCK
|
|
* * * * * * * * *
|
|
INCORRECT
|
|
2 2 3 3 4 4 5 5 7
|
|
|
|
S C S S C C S C
|
|
|
|
Notice that the position labeled 3S and 3 are swapped, and 4 was
|
|
changed to 4S.
|
|
|
|
Listed below are the revision levels that have the incorrect
|
|
silkscreen for ASSY 03-01165-01 MegaPlus II board:
|
|
|
|
REV AO
|
|
|
|
REV C
|
|
|
|
REV D
|
|
|
|
REV E
|
|
|