AST RESEARCH TECHNICAL BULLETIN TB-0039 7-31-84
|
|
|
|
|
|
MONOGRAPHPLUS WITH AMDEK MD#310A
|
|
BLANK SCREEN ON POWER UP
|
|
|
|
|
|
When using AMDEK monitor 310A and AST MonoGraphPlus card or IBM
|
|
monochrome adaptor card, an intermittent blank screen upon power
|
|
up may occur.
|
|
|
|
We have information from AMDEK Technical Group that a change
|
|
notice has been published to resolve this problem. A copy of
|
|
this notice is attached for reference.
|
|
|
|
It is suggested that AMDEK Technical Support be contacted prior
|
|
to modification of their product.
|
|
|
|
The following phone number is to be used at AMDEK Inc. for
|
|
support of this problem (312) 595-6890.
|
|
|
|
|
|
AMDEK CORP.
|
|
2201 Lively Blvd. Elk Grove Village, Illinois 60007 TLX: 25-4786
|
|
|
|
N O T I C E
|
|
|
|
When the 310A monitor is connected to the IBM-PC (or compatible)
|
|
and the character display is generated, a sympton can occur in
|
|
which the character display cannot be seen on the monitor. This
|
|
symptom can also occur when switching modes as with a Hercules
|
|
Graphics Card. Should this problem occur with your monitor we
|
|
recommend one of the following solutions:
|
|
|
|
SHORT TERM SOLUTION: Be sure to always turn on the computer
|
|
first, then the monitor.
|
|
|
|
LONG TERM SOLUTION: Locate resistor R-203 on the
|
|
motherboard inside the monitor. Disconnect or cut one leg
|
|
of the resistor from the motherboard. (When viewed from the
|
|
rear R-203 is at the top right hand corner of the
|
|
motherboard.)
|
|
|
|
This modification of the 310A will not void the two year
|
|
warranty. If you have questions or need additional assistance in
|
|
making this modification please call our technical support
|
|
department at (312) 595-6890.
|
|
|