AST RESEARCH, INC. TECHNICAL BULLETIN #0781 11-02-92
|
|
|
|
=============================================================================
|
|
|
|
|
|
PREMIUM 486/33E AND COGENT DATA TECHNOLOGIES
|
|
E/MASTER II-AT/TP ETHERNET ADAPTER
|
|
|
|
|
|
PROBLEM: Access to an Asynchronous Server fails using Netware
|
|
Asynchronous Services Interface (NASI) with a Cogent Data
|
|
Technologies E/Master II-AT/TP bus-mastering Ethernet adapter
|
|
(IPX shell version 2.32) installed in an AST Premium 486/33E
|
|
system.
|
|
|
|
CAUSE: The problem is attributed to an incompatibility with the
|
|
Ethernet Adapter IPX shell and the Premium 486/33E system.
|
|
|
|
SYSTEMS
|
|
AFFECTED: Premium 486/33 EISA
|
|
|
|
SOLUTION: To resolve this problem, customers should upgrade their Cogent
|
|
Data Technologies E/Master II Ethernet Adapter IPX shell to
|
|
version 2.41. To obtain this IPX shell contact Cogent Data
|
|
Technologies Technical Support at (206) 378-2929.
|
|
|