AST RESEARCH, INC. TECHNICAL BULLETIN #0781 11-02-92
=============================================================================
PREMIUM 486/33E AND COGENT DATA TECHNOLOGIES
E/MASTER II-AT/TP ETHERNET ADAPTER
PROBLEM: Access to an Asynchronous Server fails using Netware
Asynchronous Services Interface (NASI) with a Cogent Data
Technologies E/Master II-AT/TP bus-mastering Ethernet adapter
(IPX shell version 2.32) installed in an AST Premium 486/33E
system.
CAUSE: The problem is attributed to an incompatibility with the
Ethernet Adapter IPX shell and the Premium 486/33E system.
SYSTEMS
AFFECTED: Premium 486/33 EISA
SOLUTION: To resolve this problem, customers should upgrade their Cogent
Data Technologies E/Master II Ethernet Adapter IPX shell to
version 2.41. To obtain this IPX shell contact Cogent Data
Technologies Technical Support at (206) 378-2929.